You Searched For: BINDER INC


1,143  results were found

Sort Results

List View Easy View
SearchResultCount:"1143"
Description: Drying/heating chamber, ED056UL-120V, Standard, Series ED Avantgarde.Line with natural convection, 56 L, Voltage: 120 V 1 approx 60 Hz, Temperature range: ambient temperature +15 deg C to 300 deg C, Dimension: 360x420x380mm(inner), 560x625x565mm(outer Dimension)
Catalog Number: 75783-622
Supplier: Binder


Description: Drying/heating chamber, ED260UL-240V, Standard, Series ED Avantgarde.Line with natural convection, 260 L, Voltage: 240 V 1 approx 60 Hz, Temperature range: ambient temperature +8 deg C to 300 deg C, Dimension: 610x760x550mm(inner), 810x965x760mm(outer Dimension)
Catalog Number: 75783-630
Supplier: Binder


Description: Drying/heating chamber, ED115UL-120V, Standard, Series ED Avantgarde.Line with natural convection, 115 L, Voltage: 120 V 1 approx 60 Hz, Temperature range: ambient temperature +8 deg C to 300 deg C, Dimension: 510x530x425mm(inner), 710x735x605mm(outer Dimension)
Catalog Number: 75783-626
Supplier: Binder


Description: APT.Line* preheating technology. RS-422 port. Type 304 stainless steel chamber walls. Chamber volume: 400L. With 2 shelves (10 max.). Exterior: 123.4Wx76.5Dx103Hcm. Temperature range: ambient +5 to 300[degree]C. 208V, 50/60Hz, 3400W.
Catalog Number: 47746-762
Supplier: Binder

UL Listed


Description: APT.Line* preheating technology. RS-232 port. Type 304 stainless steel chamber walls. Chamber volume: 20L. With 2 shelves (3 max.). Exterior: 43.3Wx51.6Dx49.2Hcm. Temperature range: ambient +5 to 300[degree]C. 115V, 50/60Hz, 800W.
Catalog Number: 47746-794
Supplier: Binder

UL Listed cUL Listed


Description: VWR Vacuum drying chamber for flammable solvents, series VDL, Standard, Version: VDL023UL-120V, 0.8cu.ft, 120V 1ph 50/60 Hz, Temperature range: +9 C above ambient temperature to +110 deg C, Intuitive touchscreen controller with graphical pressure and temperature display, 2 aluminum expansion rack
Catalog Number: 76458-916
Supplier: Binder


Description: VWR Vacuum drying chamber for flammable solvents, series VDL, Standard, Version: VDL056UL-120V, 1.9 cu.ft, 120V 1 ph 50/60Hz, Temperature range: +9 C above ambient temperature to +110 deg C, Intuitive touchscreen controller with graphical pressure and temperature display, 2 aluminum expansion rack
Catalog Number: 76458-918
Supplier: Binder


Description: VWR Vacuum drying chamber for non-flammable solvents, series VD, Standard, Version: VD056UL-120V, 1.9 cu.ft, 120 V 1 ph 60 Hz, Temperature range: +9 deg C above ambient temperature to +220 deg C, Inert gas connection, Shatterproof, spring-mounted safety glass panel, 1 aluminum expansion rack
Catalog Number: 76458-912
Supplier: Binder


Description: VWR Vacuum drying chamber for flammable solvents, series VDL, Standard, Version: VDL115UL-120V, 4.2 cu.ft, 120V 1 ph 50/60Hz, Temperature range: +9 C above ambient temperature to +110 deg C, Intuitive touchscreen controller with graphical pressure and temperature display, 2 aluminum expansion rack
Catalog Number: 76458-920
Supplier: Binder


Description: VWR Vacuum module with vacuum pump VAP 2 - 120 V / 50-60 Hz, chemical membrane pump 4.0 m3/h, final pressure 1.8 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media), incl. Parts for connection, with switchable power socket, for: VD 56 Vacuum drying chamber
Catalog Number: 76458-946
Supplier: Binder


Description: VWR Vacuum drying chamber for non-flammable solvents, series VD, Standard, Version: VD115UL-120V, 4.2 cu.ft, 120 V 1 ph 60 Hz, Temperature range: +9 deg C above ambient temperature to +220 deg C, Inert gas connection, Shatterproof, spring-mounted safety glass panel, 1 aluminum expansion rack
Catalog Number: 76458-914
Supplier: Binder


Description: VWR Vacuum pump VAP 2 - 120 V / 50-60 Hz option model, Chemical membrane pump with nominal pumping speed 4,0 m raised to 3 /h, final pressure 1.8 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media)
Catalog Number: 76458-924
Supplier: Binder


Description: VWR Vacuum drying chamber for non-flammable solvents, series VD, Standard, Version: VD023UL-120V, 0.8 cu.ft, 120 V 1 ph 60 Hz, Temperature range: +9 deg C above ambient temperature to +220 deg C, Inert gas connection, Shatterproof, spring-mounted safety glass panel, 1 aluminum expansion rack
Catalog Number: 76458-910
Supplier: Binder


Description: VWR Vacuum module with vacuum pump VAP 1 - 120 V / 50-60 Hz, chemical membrane pump 2.0 m3/h, final pressure 7 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media), incl. Parts for connection, with switchable power socket, for: VD 56 Vacuum drying chamber
Catalog Number: 76458-940
Supplier: Binder


Description: VWR Vacuum module with vacuum pump VAP 1, 120V/50-60Hz, chemical membrane pump 2.0m3/h, final pressure 7 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media), incl. Parts for connection, with switchable power socket, for: VD 23 Vacuum drying chamber
Catalog Number: 76458-938
Supplier: Binder


Description: VWR Vacuum pump VAP 1 - 120 V / 50-60 Hz option model, Chemical membrane pump with nominal pumping speed 2.0 m raised to 3 /h, final pressure 7 mbar, ATEX conformity: II 3G IIC T3 X (only for interior, areas coming in contact with media)
Catalog Number: 76458-922
Supplier: Binder


1 - 16 of 1,143