Protector® ClassMate™ Laboratory Hoods, Labconco®

Supplier: Labconco
Protector® ClassMate®
160505121 160504100 160404121 160405101 160604120 160405100 160605101 160605102 160504101 160404101 160505120 160404120 160404102 160604121 160604100 160604102 160605121 160505100 160405120 160505102 160405121 160405102 160604101 160505101 160605100 160404100 160605120 160504120 160504102 160504121
76045-622EA 22048.9 CAD
76045-622 76045-644 76045-620 76045-642 76045-922 76045-648 76045-626 76045-920 76045-646 76045-624 76045-640 76045-618 76045-916 76045-616 76045-638 76045-914 76045-918 76045-654 76045-632 76045-652 76045-630 76045-636 76045-912 76045-656 76045-634 76045-910 76045-650 76045-628 76045-908 76045-906
Protector® ClassMate™ Laboratory Hoods, Labconco®
Fume Hoods and Enclosures Chemical Fume Hoods
ClassMate™ laboratory hoods are designed to meet the needs of instructional laboratories.

  • High-performance, bypass airflow design

Clear tempered safety glass provides excellent visibility even when hoods are placed back to back

The hood frame, spill trough, and standard hood air foil are constructed of glacier white powder-coated steel and aluminum. The low-profile spill trough is 3.2 cm (11/4”) deep and requires no cabinet overhang. All hoods include pre-wired LED lighting, ADA-compliant light and blower switches, removable interior cover plates for easy plumbing access, and a 12” (30.5 cm) dia. exhaust connection. A tissue screen below the exhaust outlet protects the remote blower from debris.

High-performance, 3-piece baffle pivots for cleaning. The glass front is 371/2” (95.25 cm) high, 0.6 cm (1/4”) thick, and at a 5° angle. The vertical-rising sash of the combination style hoods also include horizontal-sliding panels.

All hoods feature a high-performance, bypass airflow design. Baffles direct airflow to the rear of the interior. A pivoting air foil features a trough for secondary spill containment. Models with a combination style sash, which adds energy-saving and ergonomic benefits, are available.

Certifications: ETL listed. All hoods conform to the following regulations and standards: SEFA 1, CFR 29 Part 1910, NFPA 45, ASTM E84, ASHRAE 110, ANSI Standard Z9.5, UL 61010-1, UL 1805, CAN/CSA C22.2 No. 61010.1, SEFA 8 Cabinet Surface Finish Tests.

Ordering information: Hoods require a remote blower, ductwork, work surface (see SpillStopper models 9600400 and 9600402 series), and base cabinet(s). Hoods are factory-prepared for up to 8 service fixtures, two duplex electrical receptacles, and airflow monitor. All hoods are supplied with two LED bulbs. Hoods supplied with fixtures include one pre-wired 115V, 20A GFCI electrical duplex receptacle. On standard hoods with fixtures, two fixtures are pre-plumbed, with forged brass valves. One of the fixtures is plumbed with 0.6 cm (1/4”) copper tubing for cold water; the other fixture is plumbed with 0.6 cm (1/4”) brass tubing for use with gas. Components for converting either or both fixtures to air and vacuum are provided.
Order Now

Learn more