Pierce™ Slide-A-Lyzer® Dialysis Cassettes, Thermo Scientific

Supplier: Thermo Scientific
Slide-a-Lyzer®
66335 66453 66456 66203 66380 66710 66230 66205 66012 66384 66707 66373 66005 66380 66384 66707 66212 66203 66372 66330 66370 66456 66381 66381 66454 66383 66807 66130 66130 66332 66012 66330 66030 66372 66830 66005 66003 66385 66003 66110 66107 66455 66455 66454 66382 66811 66453 66030 66385 66205 66333 66810 66807 66373 66811 66107 66333 66230 66332 66335 66110 66710 66370 66810 66830 66212 66382 66383
CAPI66810PK 341.94 CAD
PI66205 PI66203 PI66005 PI66003 CAPI66810 CAPI66811 CAPI66384 CAPI66385 CAPI66380 CAPI66381 CAPI66382 CAPI66383 PI66373 PI66330 PI66372 PI66130 CAPI66807 PI66370 PI66810 PI66811 PI66335 PI66456 CAPI66205 PI66454 PI66333 PI66212 PI66455 PI66012 PI66453 PI66332 CAPI66454 CAPI66333 PI66807 CAPI66012 CAPI66455 CAPI66456 CAPI66335 CAPI66373 CAPI66330 CAPI66212 CAPI66332 CAPI66453 CAPI66370 CAPI66372 CAPI66130 PI66384 PI66385 PI66382 PI66383 PI66380 PI66381 PI66107 CAPI66203 CAPI66005 CAPI66003 PI66230 PI66110 PI66030 PI66830 CAPI66107 PI66710 CAPI66707 CAPI66110 CAPI66830 CAPI66230 PI66707 CAPI66710 CAPI66030
Pierce™ Slide-A-Lyzer® Dialysis Cassettes, Thermo Scientific
Tubing Dialysis Tubing
For sample dialysis, low molecular weight contaminant removal, buffer exchange, desalting, equilibrium dialysis, and concentration. This type of membrane is compatible with a number of common chemicals and buffers. The colour-coded transparent frames of the Slide-A-Lyzer® cassette allow instant recognition of the MWCO of the membrane and make viewing the needle easier during sample injection.

  • Quick and convenient
  • Durable and high recovery
  • Plastic construction

Require approximately half the time of traditional dialysis tubing and produce sample volume recoveries of more than 95%.

Gamma-irradiated Slide-A-Lyzer Dialysis Cassettes are ideal for researchers culturing cells and microorganisms; purifying viruses, DNA and RNA; or performing sample preparation for other applications requiring conditions that minimize the risk of sample contamination. The gamma-irradiated cassettes are treated with 20 to 36 kGy of gamma radiation, a dosage that has been determined to sterilize the units based on both trypticase soy broth medium for identifying total growth and fluid thioglycollate medium for identifying anaerobic growth. However, a confirmation of sterility is not provided for individual lots, as no further sterility testing is conducted post irradiation.

These cassettes are constructed of two inward-facing parallel membranes separated by a silicone-like gasket and surrounded by a plastic frame. Samples are inserted and removed by using a needle and syringe at one of the four holes located on the corners of the cassette frame. Gasket reseals following needle punctures, preventing sample loss. Hermetically sealed chambers preserve the highest possible sample integrity. Plastic frame is convenient for labeling and permits handling of the cassette without disturbing the membrane. No gloves required for use. Cassette membranes are 0.45 mil thick, except extra-strength cassette membranes, which are 1.2 mil thick.

Hydrate in one minute or less.
Order Now

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Learn more About VWR