Pierce™ Protein Concentrators PES, Thermo Scientific

Supplier: Thermo Scientific
88537 88522 88525 88515 88523 88533 88524 88521 88514 88525 88527 88535 88522 88536 88517 88526 88523 88529 88524 88536 88529 88521 88537 88531 88526 88515 88516 88527 88514 88528 88534 88531 88534 88516 88532 88533 88517 88532 88528 88535
CA10861-630PK 594.15 CAD
CA10861-630 CA10861-532 CA10861-598 CA10861-632 CA10861-610 CA10861-534 10837-450 10837-472 10837-470 10837-464 10837-462 10837-446 10837-468 10837-444 10837-466 CA10861-628 CA10861-606 10837-448 CA10861-608 CA10861-602 CA10861-624 CA10861-604 CA10861-626 CA10861-620 CA10861-622 CA10861-600 10837-460 10837-476 10837-454 10837-330 10837-474 10837-452 10837-458 10837-334 10837-312 10837-456 CA10861-616 CA10861-618 CA10861-612 CA10861-614
Pierce™ Protein Concentrators PES, Thermo Scientific
Concentrators
Protein Concentrators PES are disposable ultrafiltration centrifugal devices with a polyethersulfone (PES) membrane for concentration, desalting, and buffer exchange of biological samples.

  • Molecular weight cutoff
  • Can be used for processing sample volumes
  • Rapid protein concentration
  • Excellent protein recovery
  • Versatile sample concentrations, diafiltrations, or buffer-exchange of biological samples
  • Reliable, consistent results

Pierce™ Protein Concentrators PES are disposable ultrafiltration centrifugal devices with a polyethersulfone (PES) membrane for concentration, desalting, and buffer exchange of biological samples. This product has a molecular weight cutoff (MWCO) and can be used for processing various sample volumes. Protein Concentrators may be used in both fixed angle and swing bucker rotors; collect and recover sample without invert spinning.

For easy identification, the MWCO value is etched on the side of each device. To assist with sample addition and recovery, a clear window with graduations is located on the side of each device enabling visual determination of the retentate volume. The vertical design of the membrane allows high flux rates, low nonspecific binding, and negligible protein aggregation on the membrane; and it offers reliable and consistent results.

Pierce™ Protein Concentrators PES contain a membrane rated for retaining molecules with a molecular weight at least twofold greater than the MWCO rating of the PES membrane within the device. Reduced recovery may occur when using a concentrator with molecules smaller than the recommended mass. Protein recovery will vary depending on the specific protein in the sample and its starting concentration. To achieve greater than 90% recovery of protein, the minimum protein sample concentration should be 0.1 mg/mL.

Ordering information: For research use only. Not for use in diagnostic procedures.
Order Now

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Learn more About VWR